Skip to main content
Fans

FUA

The fans in the FUA series can be used as a direct mount fan for metal and hose tube extraction arms or as a central fan in small extraction systems.

Features
  • Low noise level
  • Direct mount
  • Rotational outlet

The FUA is a flexible direct-mount fan for Plymovent's systems

The FUA series ventilation fans are designed for direct mounting on our metal- and hose tube extraction arms and filters or for use as central fans. These fans are equipped with lightweight aluminium impellers, suitable for extracting exhaust gases, volatile fumes and dust. Matched inlet and outlet areas provide, together with the optimized impellers, an even airflow, high capacity and low noise level.

This fan needs a partner in crime

The FUA can be attached to the following extraction arms:

  • EconomyArm (EA)
    Hose tube extraction arm recommended for; maintenance welding, low usage and workbench applications.
     
  • KUA
    Metal tube extraction arm recommended for; maintenance- and production welding and workbench applications. Ideal for medium-sized workplaces.
     
  • MultiSmart Arm
    Metal tube extraction arm recommended for; production welding, plasma cutting and dust/ mist collection.
     
  • LM-2 Junior Arm
    Telescopic hose tube extraction arm recommended for; maintenance welding, welding booths and benchwork.

Step up your game against exhaust gas, welding fumes, dust and oil mist with one of these options

  • FUA-1800; 0.75 Hp / 0.55 kW
  • FUA-2100; 1 Hp / 0.75 kW
  • FUA-2700; 1.5 Hp / 1.1 kW
  • FUA-3000; 2 Hp / 1.5 kW
  • FUA-4700; 3 Hp / 2.2 kW

Features

  • Direct mount
  • Low noise level
  • Rotational outlet

Recommended for

  • Small extraction systems for vehicle exhausts removal, welding fumes, oil mist and dust.

Didn't find what you were looking for?

Our experts will be pleased to help you find a solution for your unique situation! Click here to get in touch with them.

FUA 50Hz

Physical dimensions and properties
Material:
fan
aluminium
housing
sheet metal
Colour:
motor
black (RAL 9005)
housing
grey (RAL 7011)
Motor design
IEC 60072
Fan type
radial
Design conditions
20°C (68°F) at sea level
Max. airflow temperature
80°C/176°F
Performance
Speed
2800 rpm
Max. starts/stops per hour
30
Electrical data
Insulation class
F
Protection class
IP 55
Ambient conditions
Operating temperature:
min.
5°C (41°F)
nom.
20°C (68°F)
max.
40°C (104°F)
Max. relative humidity
80%
Outdoor use allowed
no
Storage conditions
5-40°C (41-104°F), relative humidity max. 80%
Scope of supply
Fan – Connection flange with grid
Shipping data
Harmonized Tariff Code
8414.5940.90
Number/package
1

FUA 60Hz

Physical dimensions and properties
Material:
fan
aluminium
housing
sheet metal
Colour of housing
grey (RAL 7035)
Motor design
NEMA
Fan type
centrifugal
Impeller
backward inclined
Design conditions
20°C (68°F) at sea level
Max. airflow temperature
80°C/176°F
Performance
Max. starts/stops per hour
30
Ambient conditions
Operating temperature:
min.
-20°C (-4°F)
nom.
20°C (68°F)
max.
40°C (104°F)
Max. relative humidity
80%
Outdoor use allowed
no
Storage conditions
-20 to 40°C (-4 to 104°F), relative humidity max. 80%
Scope of supply
Extraction fan
Shipping data
Harmonized Tariff Code
8414.5940.90
Number/package
1
en

FUA 50Hz Product Data Sheet EN

Product data sheet
en

FUA 60Hz Product Data Sheet EN

Product data sheet
en

FUA 50Hz Manual EN

Manual
en

FUA 60Hz Manual EN

Manual
en

FUA CE Declaration EN

Certificate
ce-mark-yellow.png

The FUA is in accordance with the following directives:

• Machine Directive 2006/42 EC
• EMC 2014/30 EU
• LVD 2014/35 EU
• ErP Directive 2009/125 EC

rohs logo.png

Directive 2011/65/EC (RoHS) valid as of 8 June 2011

Doesn't fit your needs?

Take a look at these options!

Sound Absorbing Fan (SAF)

Fans

Don't give hearing damage a chance! The Sound Absorbing Fan (SAF) reduces noise by more than 10 dB, reducing the risk of hearing damage. The exhaust fans from the SAF series are equipped with sound insulation and designed for any space, indoors or outdoors, where noise pollution needs to be controlled.

SIF

Fans

The extraction fans in the SIF series are sound-insulated and designed for use in central welding fume extraction systems or general filtration systems. 3-22 kW (4.0-30 hp)

FAN-28

Fans

The FAN-28 is a wall-mounted extraction fan that provides extraction for plastic tube extraction arms with and without filtration. 0.75 kW

FAN-42

Fans

The FAN-42 is a wall-mounted extraction fan that provides extraction for plastic tube extraction arms being part of a small central filter system. 1.5 kW (2 HP)

TEV 50Hz

Fans

The TEV series ventilation fans are designed for use as central fans in larger systems with multiple extraction points. 0.75-7.5 kW (1.0-10.0 hp)

TEV 60Hz

Fans

The TEV 60 Hz series ventilation fans are designed for use as central fans in larger systems with multiple extraction points. 1.5-11,0 kW (2,0-15.0 hp)

MNF

Fans

The MNF is a portable extraction fan for use in welding operations in vessels and other confined spaces used for light to medium-intensity welding. 0.75 kW / 1 Hp

We're happy to help!

Contact our specialists now and get answers on all your questions regarding clean air.

Sign up to newsletter

Stay up to date

Contact form

Reach out to us

Nearest locations

Find out where we are